Aquatec Group Ltd HYDROlog 3100
$ 0,00
The HYDROlog 3100 instruments take the core functionality of the new HYDROlog 3000 subsea units and combine them with robust cases and user friendly interfaces to create deck versions. This allows surface training and testing to be completed wit…
Description
The HYDROlog 3100 instruments take the core functionality of the new HYDROlog 3000 subsea units and combine them with robust cases and user friendly interfaces to create deck versions. This allows surface training and testing to be completed with ease, as well as making onshore hydrotesting cost-effective and efficient. Available in a variety of models, the new deck logger range is a valuable tool for testing.
The rugged cases contain a single panel with all connectors in the interior, making it easy to transport without damage. The instruments are available with an optional integrated tablet, removing the need for a separate PC. If external power is not available, the HYDROlog 3100 can be supplied with internal batteries. The HYDROlog 3100PT measures ambient temperature and test pressure to 1400bar, with ±0.05%FS accuracy and ±0.01%FS precision pressure (to 1000bar). The HYDROlog 3100PT is available in two additional models – one measuring gauge pressure, and one measuring two test pressures in the same compact and efficiently designed instrument. The HYDROlog 3100F is a flow monitoring instrument with additional test pressure and ambient temperature sensors. The standard model monitors 1 external flow sensor, with custom options are available for multi-channel flow monitoring.
Additional information
Sensor type | Piezo-resistive bridge |
---|---|
Communication | RS232 or RS422 and USB |
Brand | Aquatec Group Ltd |
Flow sensor type | 5V TTL or Sine wave |
Weight | |
Material | Injection moulded resin |
Attachment | ¼” NPT, BSP or Autoclave |
Software | AQUAtalk for Windows for configuration and download |
Battery | 4 x ‘AA’ cells – selected from alkaline, lithium or NiMH |
External interfaces | AQUAdisp subsea display, AQUAmodem Op2 optical modem |
Burst averaging | Flexible averaging of multiple samples within burst |
Ranges | Absolute, 301, 601, 1001, 1201, 1401 bar |
Acquisition rate | Up to 8 Hz depending on sensor |
Sampling | Burst or continuous |
Data retention | >20 years |
Logging lifetime | Depends on logging parameters – up to 1 year |
Data storage capacity | 64MB in non-volatile FLASH (standard) Up to 2GB (upgrade) |
Parameters | Test pressure, ambient temperature, battery voltage, flow rate, flowed total volume, concentration (on custom version) |
Resolution | 0.002% full scale |
Precision | ±0.01% full scale over temp range (to 1000bar) ±0.05% full scale over temp range (to 1400bar) |
Accuracy | ±0.05% full scale over temp range |
Addres | Aquatec Group Ltd Aquatec House, Stroudley Road RG24 8FW Basingstoke United Kingdom |